Loading AI tools
Theoretical source of visible light From Wikipedia, the free encyclopedia
A standard illuminant is a theoretical source of visible light with a spectral power distribution that is published. Standard illuminants provide a basis for comparing images or colors recorded under different lighting.
This article is missing information about ISO 7589 standard illuminants; CIE indoor ID50 and ID65 illuminants; CIE FL3.1 through FL3.15 "new fluorescent" illuminants; CIE HP "high-pressure discharge" illuminants, all found with references in sds.py. (January 2024) |
The International Commission on Illumination (usually abbreviated CIE for its French name) is the body responsible for publishing all of the well-known standard illuminants. Each of these is known by a letter or by a letter-number combination.
Illuminants A, B, and C were introduced in 1931, with the intention of respectively representing average incandescent light, direct sunlight, and average daylight. Illuminants D (1967) represent variations of daylight, illuminant E is the equal-energy illuminant, while illuminants F (2004) represent fluorescent lamps of various composition.
There are instructions on how to experimentally produce light sources ("standard sources") corresponding to the older illuminants. For the relatively newer ones (such as series D), experimenters are left to measure to profiles of their sources and compare them to the published spectra:[1]
At present no artificial source is recommended to realize CIE standard illuminant D65 or any other illuminant D of different CCT. It is hoped that new developments in light sources and filters will eventually offer sufficient basis for a CIE recommendation.
— CIE, Technical Report (2004) Colorimetry, 3rd ed., Publication 15:2004, CIE Central Bureau, Vienna
Nevertheless, they do provide a measure, called the metamerism index, to assess the quality of daylight simulators.[2][3] The Metamerism Index tests how well five sets of metameric samples match under the test and reference illuminant. In a manner similar to the color rendering index, the average difference between the metamers is calculated.[4]
The CIE defines illuminant A in these terms:
CIE standard illuminant A is intended to represent typical, domestic, tungsten-filament lighting. Its relative spectral power distribution is that of a Planckian radiator at a temperature of approximately 2856 K. CIE standard illuminant A should be used in all applications of colorimetry involving the use of incandescent lighting, unless there are specific reasons for using a different illuminant.
The spectral radiant exitance of a black body follows Planck's law:
At the time of standardizing illuminant A, both (which does not affect the relative SPD) and were different. In 1968, the estimate of c2 was revised from 0.01438 m·K to 0.014388 m·K (and before that, it was 0.01435 m·K when illuminant A was standardized). This difference shifted the Planckian locus, changing the color temperature of the illuminant from its nominal 2848 K to 2856 K:
In order to avoid further possible changes in the color temperature, the CIE now specifies the SPD directly, based on the original (1931) value of c2:[1]
The coefficients have been selected to achieve a normalized SPD of 100 at 560 nm. The tristimulus values are (X, Y, Z) = (109.85, 100.00, 35.58), and the chromaticity coordinates using the standard observer are (x, y) = (0.44758, 0.40745).
Illuminants B and C are easily achieved daylight simulations. They modify illuminant A by using liquid filters. B served as a representative of noon sunlight, with a correlated color temperature (CCT) of 4874 K, while C represented average day light with a CCT of 6774 K. Unfortunately, they are poor approximations of any phase of natural daylight, particularly in the short-wave visible and in the ultraviolet spectral ranges. Once more realistic simulations were achievable, illuminants B and C were deprecated in favor of the D series.[1]
Illuminant C does not have the status of CIE standard illuminants but its relative spectral power distribution, tristimulus values and chromaticity coordinates are given in Table T.1 and Table T.3, as many practical measurement instruments and calculations still use this illuminant.
— CIE, Publication 15:2004[5]
Illuminant B was not so honored in 2004.
The liquid filters, designed by Raymond Davis and Kasson S. Gibson in 1931,[6] have a relatively high absorbance at the red end of the spectrum, effectively increasing the CCT of the incandescent lamp to daylight levels. This is similar in function to a CTB color gel that photographers and cinematographers use today, albeit much less convenient.
Each filter uses a pair of solutions, comprising specific amounts of distilled water, copper sulfate, mannite, pyridine, sulfuric acid, cobalt, and ammonium sulfate. The solutions are separated by a sheet of uncolored glass. The amounts of the ingredients are carefully chosen so that their combination yields a color temperature conversion filter; that is, the filtered light is still white.
The D series of illuminants are designed to represent natural daylight and lie along the daylight locus. They are difficult to produce artificially, but are easy to characterize mathematically.
By 1964, several spectral power distributions (SPDs) of daylight had been measured independently by H. W. Budde of the National Research Council of Canada in Ottawa, H. R. Condit and F. Grum of the Eastman Kodak Company in Rochester, New York,[7] and S. T. Henderson and D. Hodgkiss of Thorn Electrical Industries in Enfield (north London),[8] totaling among them 622 samples. Deane B. Judd, David MacAdam, and Günter Wyszecki analyzed these samples and found that the (x, y) chromaticity coordinates followed a simple, quadratic relation, later known as the daylight locus:[9]
Characteristic vector analysis revealed that the SPDs could be satisfactorily approximated by using the mean (S0) and first two characteristic vectors (S1 and S2):[10][11]
In simpler terms, the SPD of the studied daylight samples can be expressed as the linear combination of three, fixed SPDs. The first vector (S0) is the mean of all the SPD samples, which is the best reconstituted SPD that can be formed with only a fixed vector. The second vector (S1) corresponds to yellow–blue variation (along the locus), accounting for changes in the correlated color temperature due to proportion of indirect to direct sunlight.[9] The third vector (S2) corresponds to pink–green variation (across the locus) caused by the presence of water in the form of vapor and haze.[9]
By the time the D-series was formalized by the CIE,[12] a computation of the chromaticity for a particular isotherm was included.[13] Judd et al. then extended the reconstituted SPDs to 300 nm–330 nm and 700 nm–830 nm by using Moon's spectral absorbance data of the Earth's atmosphere.[14] The tabulated SPDs presented by the CIE today are derived by linear interpolation of the 10 nm data set down to 5 nm.[15] However, there is a proposal to use spline interpolation instead.[16]
Similar studies have been undertaken in other parts of the world, or repeating Judd et al.'s analysis with modern computational methods. In several of these studies, the daylight locus is notably closer to the Planckian locus than in Judd et al.[17] [18]
The CIE positions D65 as the standard daylight illuminant:
[D65] is intended to represent average daylight and has a correlated colour temperature of approximately 6500 K. CIE standard illuminant D65 should be used in all colorimetric calculations requiring representative daylight, unless there are specific reasons for using a different illuminant. Variations in the relative spectral power distribution of daylight are known to occur, particularly in the ultraviolet spectral region, as a function of season, time of day, and geographic location.
— ISO 10526:1999/CIE S005/E-1998, CIE Standard Illuminants for Colorimetry[19]
The relative spectral power distribution (SPD) of a D series illuminant can be derived from its chromaticity coordinates in the CIE 1931 color space, .[20] First, the chromaticity coordinates must be determined:
where T is the illuminant's CCT. Note that the CCTs of the canonical illuminants, D50, D55, D65, and D75, differ slightly from what their names suggest. For example, D50 has a CCT of 5003 K ("horizon" light), while D65 has a CCT of 6504 K (noon light). This is because the value of the constants in Planck's law have been slightly changed since the definition of these canonical illuminants, whose SPDs are based on the original values in Planck's law.[1] The same discrepancy applies to all illuminants in the D series—D50, D55, D65, D75—and can be "rectified" by multiplying the nominal color temperature by ; for example for D65.
To determine the D-series SPD (SD) that corresponds to those coordinates, the coefficients M1 and M2 of the characteristic vectors S1 and S2 are determined:
where are the mean and first two eigenvector SPDs, depicted in figure.[20] The characteristic vectors both have a zero at 560 nm, since all the relative SPDs have been normalized about this point. In order to match all significant digits of the published data of the canonical illuminants the values of M1 and M2 have to be rounded to three decimal places before calculation of SD.[1]
Using the standard 2° observer, the CIE 1931 color space chromaticity coordinates of D65 are[21]
and the XYZ tristimulus values (normalized to Y = 100), are
For the supplementary 10° observer,[citation needed]
and the corresponding XYZ tristimulus values are
Since D65 represents white light, its coordinates are also a white point, corresponding to a correlated color temperature of 6504 K. Rec. 709, used in HDTV systems, truncates the CIE 1931 coordinates to x=0.3127, y=0.329.
There are no actual daylight light sources, only simulators. Constructing a practical light source that emulates a D-series illuminant is a difficult problem. The chromaticity can be replicated simply by taking a well known light source and applying filters, such as the Spectralight III, that used filtered incandescent lamps.[22] However, the SPDs of these sources deviate from the D-series SPD, leading to bad performance on the CIE metamerism index.[23][24] Better sources were achieved in the 2010s with phosphor-coated white LEDs that can easily emulate the A, D, and E illuminants with high CRI.[25]
Illuminant E is an equal-energy radiator; it has a constant SPD inside the visible spectrum. It is useful as a theoretical reference; an illuminant that gives equal weight to all wavelengths. It also has equal CIE XYZ tristimulus values, thus its chromaticity coordinates are (x,y)=(1/3,1/3). This is by design; the XYZ color matching functions are normalized such that their integrals over the visible spectrum are the same.[1]
Illuminant E is not a black body, so it does not have a color temperature, but it can be approximated by a D series illuminant with a CCT of 5455 K. (Of the canonical illuminants, D55 is the closest.) Manufacturers sometimes compare light sources against illuminant E to calculate the excitation purity.[26]
The F series of illuminants represent various types of fluorescent lighting.
F1–F6 "standard" fluorescent lamps consist of two semi-broadband emissions of antimony and manganese activations in calcium halophosphate phosphor.[27] F4 is of particular interest since it was used for calibrating the CIE color rendering index (the CRI formula was chosen such that F4 would have a CRI of 51). F7–F9 are "broadband" (full-spectrum light) fluorescent lamps with multiple phosphors, and higher CRIs. Finally, F10–F12 are narrow triband illuminants consisting of three "narrowband" emissions (caused by ternary compositions of rare-earth phosphors) in the R,G,B regions of the visible spectrum. The phosphor weights can be tuned to achieve the desired CCT.
The spectra of these illuminants are published in Publication 15:2004.[5][28]
Publication 15:2018 introduces new illuminants for different white LED types with CCTs ranging from approx. 2700 K to 6600 K.
LED-B1 through B5 defines LEDs with phosphor-converted blue light. LED-BH1 defines a blend of phosphor-converted blue and a red LED. LED-RGB1 defines the white light produced by a tricolor LED mix. LED-V1 and V2 define LEDs with phosphor-converted violet light.
The spectrum of a standard illuminant, like any other profile of light, can be converted into tristimulus values. The set of three tristimulus coordinates of an illuminant is called a white point. If the profile is normalized, then the white point can equivalently be expressed as a pair of chromaticity coordinates.
If an image is recorded in tristimulus coordinates (or in values which can be converted to and from them), then the white point of the illuminant used gives the maximum value of the tristimulus coordinates that will be recorded at any point in the image, in the absence of fluorescence. It is called the white point of the image.
The process of calculating the white point discards a great deal of information about the profile of the illuminant, and so although it is true that for every illuminant the exact white point can be calculated, it is not the case that knowing the white point of an image alone tells you a great deal about the illuminant that was used to record it.
A list of standardized illuminants, their CIE chromaticity coordinates (x,y) of a perfectly reflecting (or transmitting) diffuser, and their correlated color temperatures (CCTs) are given below. The CIE chromaticity coordinates are given for both the 2 degree field of view (1931) and the 10 degree field of view (1964).[29]The color swatches represent the color of each white point, automatically calculated by Wikipedia using the Color temperature template.
Name | CIE 1931 2° | CIE 1964 10° | CCT (K) | Note | ||
---|---|---|---|---|---|---|
x2° | y2° | x10° | y10° | |||
A | 0.44758 | 0.40745 | 0.45117 | 0.40594 | 2856 | incandescent / tungsten |
B | 0.34842 | 0.35161 | 0.34980 | 0.35270 | 4874 | obsolete, direct sunlight at noon |
C | 0.31006 | 0.31616 | 0.31039 | 0.31905 | 6774 | obsolete, average / North sky daylight NTSC 1953[34], PAL-M[35][a] |
D50 | 0.34567 | 0.35850 | 0.34773 | 0.35952 | 5003 | horizon light, ICC profile PCS[a] |
D55 | 0.33242 | 0.34743 | 0.33411 | 0.34877 | 5503 | mid-morning / mid-afternoon daylight |
D65 | 0.31272 | 0.32903 | 0.31382 | 0.33100 | 6504 | noon daylight: television, sRGB color space[a] |
D75 | 0.29902 | 0.31485 | 0.29968 | 0.31740 | 7504 | North sky daylight |
D93 | 0.28315 | 0.29711 | 0.28327 | 0.30043 | 9305 | high-efficiency blue phosphor monitors, BT.2035[a], NTSC-J[36][37][38] |
E | 0.33333 | 0.33333 | 0.33333 | 0.33333 | 5454 | equal energy |
F1 | 0.31310 | 0.33727 | 0.31811 | 0.33559 | 6430 | daylight fluorescent |
F2 | 0.37208 | 0.37529 | 0.37925 | 0.36733 | 4230 | cool white fluorescent |
F3 | 0.40910 | 0.39430 | 0.41761 | 0.38324 | 3450 | white fluorescent |
F4 | 0.44018 | 0.40329 | 0.44920 | 0.39074 | 2940 | warm white fluorescent |
F5 | 0.31379 | 0.34531 | 0.31975 | 0.34246 | 6350 | daylight fluorescent |
F6 | 0.37790 | 0.38835 | 0.38660 | 0.37847 | 4150 | light white fluorescent |
F7 | 0.31292 | 0.32933 | 0.31569 | 0.32960 | 6500 | D65 simulator, daylight simulator |
F8 | 0.34588 | 0.35875 | 0.34902 | 0.35939 | 5000 | D50 simulator, Sylvania F40 Design 50 |
F9 | 0.37417 | 0.37281 | 0.37829 | 0.37045 | 4150 | cool white deluxe fluorescent |
F10 | 0.34609 | 0.35986 | 0.35090 | 0.35444 | 5000 | Philips TL85, Ultralume 50 |
F11 | 0.38052 | 0.37713 | 0.38541 | 0.37123 | 4000 | Philips TL84, Ultralume 40 |
F12 | 0.43695 | 0.40441 | 0.44256 | 0.39717 | 3000 | Philips TL83, Ultralume 30 |
LED-B1 | 0.4560 | 0.4078 | 2733 | phosphor-converted blue | ||
LED-B2 | 0.4357 | 0.4012 | 2998 | phosphor-converted blue | ||
LED-B3 | 0.3756 | 0.3723 | 4103 | phosphor-converted blue | ||
LED-B4 | 0.3422 | 0.3502 | 5109 | phosphor-converted blue | ||
LED-B5 | 0.3118 | 0.3236 | 6598 | phosphor-converted blue | ||
LED-BH1 | 0.4474 | 0.4066 | 2851 | mixing of phosphor-converted blue LED and red LED (blue-hybrid) | ||
LED-RGB1 | 0.4557 | 0.4211 | 2840 | mixing of red, green, and blue LEDs | ||
LED-V1 | 0.4548 | 0.4044 | 2724 | phosphor-converted violet | ||
LED-V2 | 0.3781 | 0.3775 | 4070 | phosphor-converted violet |
Seamless Wikipedia browsing. On steroids.
Every time you click a link to Wikipedia, Wiktionary or Wikiquote in your browser's search results, it will show the modern Wikiwand interface.
Wikiwand extension is a five stars, simple, with minimum permission required to keep your browsing private, safe and transparent.