Loading AI tools
Molecules which differ only in isotope composition From Wikipedia, the free encyclopedia
In chemistry, isotopologues (also spelled isotopologs) are molecules that differ only in their isotopic composition.[1] They have the same chemical formula and bonding arrangement of atoms, but at least one atom has a different number of neutrons than the parent.
An example is water, whose hydrogen-related isotopologues are: "light water" (HOH or H2O), "semi-heavy water" with the deuterium isotope in equal proportion to protium (HDO or 1H2HO), "heavy water" with two deuterium atoms (D2O or 2H2O); and "super-heavy water" or tritiated water (T2O or 3H2O, as well as HTO [1H3HO] and DTO [2H3HO], where some or all of the hydrogen is the radioactive tritium isotope). Oxygen-related isotopologues of water include the commonly available form of heavy-oxygen water (H218O) and the more difficult to separate version with the 17O isotope. Both elements may be replaced by isotopes, for example in the doubly labeled water isotopologue D218O. Altogether, there are 9 different stable water isotopologues,[2] and 9 radioactive isotopologues involving tritium,[3] for a total of 18. However only certain ratios are possible in mixture, due to prevalent hydrogen swapping.
The atom(s) of the different isotope may be anywhere in a molecule, so the difference is in the net chemical formula. If a compound has several atoms of the same element, any one of them could be the altered one, and it would still be the same isotopologue. When considering the different locations of the same isotope, the term isotopomer, first proposed by Seeman and Paine in 1992, is used.[4][5] Isotopomerism is analogous to constitutional isomerism or stereoisomerism of different elements in a structure. Depending on the formula and the symmetry of the structure, there might be several isotopomers of one isotopologue. For example, ethanol has the molecular formula C2H6O. Mono-deuterated ethanol, C2H5DO or C2H52HO, is an isotopologue of it. The structural formulas CH3−CH2−O−D and CH2D−CH2−O−H are two isotopomers of that isotopologue.
Singly substituted isotopologues may be used for nuclear magnetic resonance experiments, where deuterated solvents such as deuterated chloroform (CDCl3 or C2HCl3) do not interfere with the solutes' 1H signals, and in investigations of the kinetic isotope effect.
In the field of stable isotope geochemistry, isotopologues of simple molecules containing rare heavy isotopes of carbon, oxygen, hydrogen, nitrogen, and sulfur are used to trace equilibrium and kinetic processes in natural environments and in Earth's past.
Measurement of the abundance of clumped isotopes (doubly substituted isotopologues) of gases has been used in the field of stable isotope geochemistry to trace equilibrium and kinetic processes in the environment inaccessible by analysis of singly substituted isotopologues alone.
Currently measured doubly substituted isotopologues include:
Because of the relative rarity of the heavy isotopes of C, H, and O, isotope-ratio mass spectrometry (IRMS) of doubly substituted species requires larger volumes of sample gas and longer analysis times than traditional stable isotope measurements, thereby requiring extremely stable instrumentation. Also, the doubly-substituted isotopologues are often subject to isobaric interferences, as in the methane system where 13CH5+ and 12CH3D+ ions interfere with measurement of the 12CH2D2+ and 13CH3D+ species at mass 18. A measurement of such species requires either very high mass resolving power to separate one isobar from another,[13] or modeling of the contributions of the interfering species to the abundance of the species of interest. These analytical challenges are significant: The first publication precisely measuring doubly substituted isotopologues did not appear until 2004, though singly substituted isotopologues had been measured for decades previously.[14]
As an alternative to more conventional gas source IRMS instruments, tunable diode laser absorption spectroscopy has also emerged as a method to measure doubly substituted species free from isobaric interferences, and has been applied to the methane isotopologue 13CH3D.
When a light isotope is replaced with a heavy isotope (e.g., 13C for 12C), the bond between the two atoms will vibrate more slowly, thereby lowering the zero-point energy of the bond and acting to stabilize the molecule.[15] An isotopologue with a doubly substituted bond is therefore slightly more thermodynamically stable, which will tend to produce a higher abundance of the doubly substituted (or “clumped”) species than predicted by the statistical abundance of each heavy isotope (known as a stochastic distribution of isotopes). This effect increases in magnitude with decreasing temperature, so the abundance of the clumped species is related to the temperature at which the gas was formed or equilibrated.[16] By measuring the abundance of the clumped species in standard gases formed in equilibrium at known temperatures, the thermometer can be calibrated and applied to samples with unknown abundances.
The abundances of multiply substituted isotopologues can also be affected by kinetic processes. As for singly substituted isotopologues, departures from thermodynamic equilibrium in a doubly-substituted species can implicate the presence of a particular reaction taking place. Photochemistry occurring in the atmosphere has been shown to alter the abundance of 18O2 from equilibrium, as has photosynthesis.[17] Measurements of 13CH3D and 12CH2D2 can identify microbial processing of methane and have been used to demonstrate the significance of quantum tunneling in the formation of methane, as well as mixing and equilibration of multiple methane reservoirs. Variations in the relative abundances of the two N2O isotopologues 14N15N18O and {{sup>15}}N14N18O can distinguish whether N2O has been produced by bacterial denitrification or by bacterial nitrification.
Multiple substituted isotopologues may be used for nuclear magnetic resonance or mass spectrometry experiments, where isotopologues are used to elucidate metabolic pathways in a qualitative (detect new pathways) or quantitative (detect quantitative share of a pathway) approach. A popular example in biochemistry is the use of uniform labelled glucose (U-13C glucose), which is metabolized by the organism under investigation (e. g. bacterium, plant, or animal) and whose signatures can later be detected in newly formed amino acid or metabolically cycled products.
Resulting from either naturally occurring isotopes or artificial isotopic labeling, isotopologues can be used in various mass spectrometry applications.
The relative mass spectral intensity of natural isotopologues, calculable from the fractional abundances of the constituent elements, is exploited by mass spectrometry practitioners in quantitative analysis and unknown compound identification:
A compound tagged by replacing specific atoms with the corresponding isotopes can facilitate the following mass spectrometry methods:
Seamless Wikipedia browsing. On steroids.
Every time you click a link to Wikipedia, Wiktionary or Wikiquote in your browser's search results, it will show the modern Wikiwand interface.
Wikiwand extension is a five stars, simple, with minimum permission required to keep your browsing private, safe and transparent.