Loading AI tools
Explosion of a vessel containing liquid above and beyond boiling point From Wikipedia, the free encyclopedia
A boiling liquid expanding vapor explosion (BLEVE, /ˈblɛviː/ BLEV-ee) is an explosion caused by the rupture of a vessel containing a pressurized liquid that is or has reached a temperature sufficiently higher than its boiling point at atmospheric pressure.[1][2] Because the boiling point of a liquid rises with pressure, the contents of the pressurized vessel can remain a liquid as long as the vessel is intact. If the vessel's integrity is compromised, the loss of pressure drops the boiling point, which can cause the liquid to convert to gas expanding rapidly. BLEVEs are manifestations of explosive boiling.
If the gas is flammable, as is the case with e.g., hydrocarbons and alcohols, further damage can be caused by the ensuing fire. However, BLEVEs do not necessarily involve fire.
On 24 April 1957, a process reactor at a Factory Mutual (FM) facility underwent a powerful explosion as a consequence of a rapid depressurization. It contained formalin mixed with phenol. The burst damaged the plant. However, no fire developed, as the mixture was not flammable. In the wake of the accident, researchers James B. Smith, William S. Marsh, and Wilbur L. Walls, who were employed with FM, came up with the terms "boiling liquid expanding vapor explosion" and its acronym "BLEVE".[3][4] The expressions did not become of common use until the early 1970s, when the National Fire Protection Association's (NFPA) Fire Command and Fire Journal magazines started publishing articles using them.[5]
There are three key elements in the formation of a BLEVE:[6]
Typically, a BLEVE starts with a vessel containing liquid held above its atmospheric-pressure boiling temperature. Many substances normally stored as liquids, such as carbon dioxide, propane, and other industrial gases have boiling temperatures below room temperature when at atmospheric pressure. In the case of water, a BLEVE could occur if a pressure vessel is heated beyond 100 °C (212 °F). That container, because the boiling water pressurizes it, must be capable of holding liquid water at very high temperatures.
If the pressurized vessel ruptures, the pressure which prevents the liquid from boiling is lost. If the rupture is catastrophic, i.e., the vessel becomes suddenly no longer capable of holding any pressure, then the liquid will find itself at a temperature far above its boiling point. This causes a portion of the liquid to instantaneously vaporize with extremely rapid expansion. Depending on temperatures, pressures and the material involved, the expansion may be so rapid that it can be classified as an explosion, fully capable of inflicting severe damage on its surroundings.
For example, a tank of pressurized liquid water held at 350 °C (662 °F) might be pressurized to 10 MPa (1,500 psi) above atmospheric (or gauge) pressure. If the tank containing the water were to rupture, there would for a brief moment exist a volume of liquid water which would be at:
At atmospheric pressure the boiling point of water is 100 °C (212 °F). Liquid water at atmospheric pressure does not exist at temperatures higher than 100 °C (212 °F). At that moment, the water would boil and turn to vapor explosively, and the 350 °C (662 °F) liquid water turned to gas would take up significantly more volume (≈ 1,600-fold) than it did as liquid, causing a vapor explosion. Such explosions can happen when the superheated water of a boiler escapes through a crack in a boiler, causing a boiler explosion.
The vaporization of liquid resulting in a BLEVE typically occurs within 1 millisecond after a catastrophic loss of containment.[7]
For a BLEVE to occur, the boiling liquid must be sufficiently superheated upon loss of containment. For example, at a pressure of approximately 1 MPa (150 psi), water boils at 177 °C (351 °F). Superheated water released from a closed container at these conditions will not generate a BLEVE, as homogeneous nucleation of vapor bubbles is not possible.[8] There is no consensus about the minimal temperature above which a BLEVE will occur. A formula proposed by Robert Reid to predict it is:
where TC is the critical temperature of the fluid (expressed in kelvin). The minimum BLEVE temperatures of some fluids, based on this formula, are as follows:[9]
Substance | Tmin,BLEVE | ||
---|---|---|---|
K | °C | °F | |
Water | 579 | 306 | 583 |
n-Octane | 509 | 236 | 457 |
n-Heptane | 483 | 210 | 410 |
n-Hexane | 454 | 181 | 358 |
n-Pentane | 421 | 148 | 298 |
Ethyl eter | 418 | 145 | 293 |
Phosgene | 407 | 134 | 273 |
n-Butane | 381 | 108 | 226 |
Chlorine | 375 | 102 | 216 |
Ammonia | 363 | 90 | 194 |
Propane | 331 | 58 | 136 |
Propylene | 327 | 54 | 129 |
Ethane | 273 | 0 | 32 |
Carbon dioxide | 272 | –1 | 30 |
Ethylene | 253 | –20 | –4 |
Methane | 171 | –102 | –152 |
According to Reid, BLEVE will occur, more in general, if the expansion crosses a "superheat-limit locus". In Reid's model, this curve is essentially the fluid's spinodal curve as represented in a pressure–temperature diagram, and the BLEVE onset is a manifestation of explosive boiling, where the spinodal is crossed "from above", i.e., via sudden depressurization. However, direct correspondence between the superheat limit and the spinodal has not been proven experimentally. In practical BLEVEs, the way the pressure vessel fails may influence decisively the way the expansion takes place, for example causing pressure waves and non-uniformities. Additionally, there may be stratification in the liquid, due to local temperature variations. Because of this, it is possible for BLEVEs to occur at temperatures less than those predicted with Reid's formula.[10]
The term BLEVE is often associated to explosive fires from pressure vessels containing a flammable liquid. However, a BLEVE can occur even with a non-flammable substance such as water,[11] liquid nitrogen, liquid helium or other refrigerants or cryogenics. Such materials can go through purely physical BLEVEs, not entailing flames or other chemical reactions. In the case of unignited BLEVEs of liquefied gases, rapid cooling due to the absorption of the enthalpy of vaporization is a hazard that can cause frostbite. Asphyxiation from the expanding vapors is also possible, if the vapor cloud is not rapidly dispersed, as can be the case inside a building, or in a trough in the case of heavier-than-air gasses. The vapors can also be toxic, in which case harm and possibly death can occur at relatively low concentrations and, therefore, even far from the source.
If a flammable substance, however, is subject to a BLEVE, it can ignite upon release, either due to friction, mechanical spark or other point sources, or from a pre-existing fire that had engulfed the pressure vessel and caused it to fail in the first place. In such a case, the burning vapors will further expand, adding to the force of the explosion. Furthermore, a very significant amount of the escaped fluid will burn in a matter of seconds in a raising fireball, which will generate extremely high levels of thermal radiation. While the blast effects can be devastating, a flammable substance BLEVE typically causes more damage due to the fireball thermal radiation than the blast overpressure.
BLEVEs are often caused by an external fire near the storage vessel causing heating of the contents and pressure build-up. While tanks are often designed to withstand great pressure, constant heating can cause the metal to weaken and eventually fail. If the tank is being heated in an area where there is no liquid (such as near its top), it may rupture faster because the boiling liquid does not afford cooling in that area. Pressure vessels are usually equipped with relief valves that vent off excess pressure, but the tank can still fail if the pressure is not released quickly enough.[1] A pressure vessel is designed to withstand the set pressure of its relief valves, but only if its mechanical integrity is not weakened as it can be in the case of an impinging fire.[12] In an impinging fire scenario, flammable vapors released in the BLEVE will ignite upon release, forming a fireball. The origin of the impinging fire may be from a release of flammable fluid from the vessel itself, or from an external source, including releases from nearby tanks and equipment. For example, rail tank cars have BLEVEd under the effect of a jet fire from the open relief valve of another derailed tank car.[13]
The main damaging effects of a BLEVE are three: the blast wave from the explosion; the projection of fragments, or missiles, from the pressure vessel; and the thermal radiation from the fireball, where one occurs.[12]
Horizontal cylindrical ("bullet") tanks tend to rupture longitudinally. This causes the failed tank and its fragments to get propelled like rockets and travel long distances.[14] At Feyzin, three of the propelled fragments weighed in excess of 100 tons and were thrown 150–350 meters (490–1150 ft) from the source of the explosion. One bullet tank at San Juanico travelled 1,200 meters (0.75 mi) in the air before landing, possibly the farthest ever for a BLEVE missile.[15] Fragments can impact on other tanks or equipment, which may result in a domino effect propagation of the accidental sequence.[7]
Fireballs can rise to significant heights above ground.[14] They are spheroidal when developed and rise from the ground in a mushroom shape.[7] The diameter of fireballs at San Juanico was estimated at 200–300 meters (660–980 ft), with a duration of around 20 seconds. Such massive fires can injure people at distances of hundreds of meters (e.g., 300 m (980 ft) at Feyzin and 400 m (1310 ft) at San Juanico).[14]
An additional hazard from BLEVE-fireball events is the formation of secondary fires, by direct exposure to the fireball thermal radiation, as pool fires from fuel that does not get combusted in the fireball, or from the scattering of blazing tank fragments.[15][7] Another secondary effect of importance is the dispersion of a toxic gas cloud, if the vapors involved are toxic and do not catch fire upon release.[7] Chlorine, ammonia and phosgene are example of toxic gases that underwent BLEVE in past accidents and produced toxic clouds as a consequence.[7]
Notable BLEVE accidents include:
Seamless Wikipedia browsing. On steroids.
Every time you click a link to Wikipedia, Wiktionary or Wikiquote in your browser's search results, it will show the modern Wikiwand interface.
Wikiwand extension is a five stars, simple, with minimum permission required to keep your browsing private, safe and transparent.