Automotive fuse

Class of fuses used to protect the wiring and electrical equipment for vehicles From Wikipedia, the free encyclopedia

Automotive fuse

Automotive fuses are a class of fuses used to protect the wiring and electrical equipment for vehicles. They are generally rated for circuits no higher than 32 volts direct current, but some types are rated for 42-volt electrical systems. They are occasionally used in non-automotive electrical products. Automotive fuses are typically housed inside one or more fuse boxes (also called an integrated power module (IPM)) within the vehicle, typically on one side of the engine compartment and/or under the dash near the steering wheel. Some fuses or circuit breakers may nonetheless be placed elsewhere, such as near the cabin fan or air bag controller. They also exist as circuit breakers that are resettable using a switch.[1]

Thumb
Mini / Regular / Maxi blade-type automotive fuses, side and top views. The top metal surfaces can be tested using multimeter probes.
Thumb
Automobile electrical circuit breaker with resettable switch

There may be a fuse for ignition off draw (IOD), which controls the drawing of electric current in a vehicle while it is shut off; removing this fuse while the vehicle is shut off for more than a few weeks will prevent excessive depletion of the battery.[citation needed]

Blade type

Summarize
Perspective
Blade type fuses come in six physical sizes: Micro2, Micro3, low-profile (LP) Mini, Mini, Regular, Maxi

Blade fuses (also called spade or plug-in fuses), with a plastic body and two prongs that fit into sockets, are mostly used in automobiles. Other common usage is in equipment with comparatively simple, low voltage DC electrical systems such as towed campers and marine applications such as sailboats and motor boats (typically smaller cabin cruisers).

Each fuse is printed with the rated current in amperes on the top.

These types of fuses come in six different physical dimensions:

  • Micro2.
  • Micro3.
  • LP-mini (APS), also known as low-profile mini. Unofficially, the "low-profile mini" fuse is sometimes incorrectly called "Micro" since the term means smaller than mini, but recently fuses using the Micro name have been released.
  • Mini (APM / ATM). The mini fuses were developed in the 1990s.
  • Regular (APR / ATC / ATO / ATS) blade-type fuses, also known as standard, were developed in 1976 as ATO by Littelfuse[2] for low voltage use in motor vehicles. Bussmann makes the ATC[3] that also complies with the same ISO 8820-3 and SAE J1284 standards. OptiFuse, a newer entrant in the market, makes regular (APR / ATC / ATO) fuses that meet the same standards.[4]
  • Maxi (APX), heavy-duty.

Mount

Blade fuse holder on Citroën Jumper

Blade type fuses can be mounted in:

  • Fuse blocks (made of porcelain, slate, or other refractory material).
  • In-line fuse holders
  • Dual slot fuse holders
  • Fuse clips.

Size groups

More information Blade size, Blade group ...
Blade sizeBlade groupDimensions L × W × HCommon ratings (maximum current)
Micro2APT, ATR9.1 × 3.8 × 15.3 mm5, 7.5, 10, 15, 20, 25, 30
Micro3ATL14.4 × 4.2 × 18.1 mm5, 7.5, 10, 15
LP-Mini
(low profile)
APS, ATT10.9 × 3.81 × 8.73 mm2, 3, 4, 5, 7.5, 10, 15, 20, 25, 30
MiniAPM, ATM10.9 × 3.6 × 16.3 mm2, 3, 4, 5, 7.5, 10, 15, 20, 25, 30
RegularAPR, ATC,[3] ATO,[2] ATS[5]19.1 × 5.1 × 18.5 mm0.5, 1, 2, 3, 4, 5, 7.5, 10, 15, 20, 25, 30, 35, 40
MaxiAPX29.2 × 8.5 × 34.3 mm20, 25, 30, 35, 40, 50, 60, 70, 80, 100, 120
Close

Where space permits, a miniature circuit breaker is sometimes used to replace a blade-type fuse in the same fuse holder.

Blade fuses use a common coloring scheme for the Micro2, Micro3, low-profile (LP) Mini, Mini, and regular size fuses, and a partial color similarity with the maxi size fuses. The following table shows the commonly available fuses for each size group.

More information Color, Current rating ...
ColorCurrent ratingMicro2Micro3LP
Mini
MiniRegMaxi
 Dark blue0.5 ANoNoNoNoYesNo
 Black1 ANoNoNoNoYesNo
 Grey2 ANoNoYesYesYesNo
 Violet3 ANoNoYesYesYesNo
 Pink4 ANoNoYesYesYesNo
 Tan5 AYesYesYesYesYesNo
 Brown7.5 AYesYesYesYesYesNo
 Red10 AYesYesYesYesYesNo
 Blue15 AYesYesYesYesYesYes
 Yellow20 AYesNoYesYesYesYes
 Transparent25 AYesNoYesYesYes Grey
 Green30 AYesNoYesYesYesYes
 Blue-green35 ANoNoYesYesYes Brown
 Orange40 ANoNoYesYesYesYes
 Red50 ANoNoNoNoNoYes
 Blue60 ANoNoNoNoNoYes
 Amber/tan70 ANoNoNoNoNoYes
 Transparent80 ANoNoNoNoNoYes
 Violet100 ANoNoNoNoNoYes
 Purple120 ANoNoNoNoNoYes
Close

Regular fuses (ATO) rated 0.5 A, 35 A and 40 A are not mentioned in the DIN standards,[6] but are available in some products from Littelfuse, among others.

Cartridge type

Several cartridge type fuses are used in automotive applications, including MCASE, MCASE+,[7] JCASE,[8] and low-profile JCASE types.[9]

Bosch type

Thumb
Bosch type fuse (used in older cars)
Thumb
A Bosch fuse box for porcelain fuses in a 1933 Alfa Romeo 6C 1750

Bosch type fuses (also known as ceramic, porcelain, continental, torpedo, European, or GBC type fuses) are used in old (often European) automobiles. The physical dimension of this type of fuse is 6×25 mm with conical ends. Bosch type fuses usually use the same color-coding for the rated current. The DIN standard is 72581/1.

Color coding

More information Color, Current rating ...
ColorCurrent rating
 Yellow5 A
 White8 A
 Red16 A
 Blue25 A
 Grey40 A
Close

Lucas type

Summarize
Perspective

Lucas type fuses are used in old British-made or assembled automobiles. The physical length of the Lucas ceramic type of fuse is either 1 inch or 1.25 inch, with conical ends. Lucas glass tube fuses have straight ends. Lucas type fuses usually use the same color-coding for the rated current. Lucas fuses have three ratings; the continuous current they are designed to carry, the instantaneous current at which they will fuse, and the continuous current at which they will also fuse. The figure found on Lucas fuses is the continuous fusing current which is twice the continuous ampere rating that the system should be using; this can be a source of confusion when replacing Lucas fuses with non Lucas fuses. The Lucas 1/4" diameter glass tube fuse have a different length as compared to the standard US item. The Lucas 1/4" diameter glass tube fuse is 1+532 in (29 mm) long, while the US standard 1/4" glass tube fuse is 1+14 in (32 mm)] long. However, many Lucas fuse holders permit the longer US version to be installed easily.

Color coding

More information Color, Continuous ampere (=rated current) ...
Color Continuous ampere (=rated current) Instantaneous fusing ampere Continuous fusing ampere
Blue 1.5 3.5 3
Yellow 2.25 5 4.5
Red on yellow 2.5 6 5
Green 3 7 6
Nut brown 4 10 8
Red on green 5 12 10
Green on black 5 12 10
Red on brown 6 14 12
Light brown 7.5 18 15
Pink 12.5 30 25
White 17.5 40 35
Purple on yellow 25 60 50
Yellow on red 30 75 60
Close

Glass tube type

Summarize
Perspective
Thumb
Glass tube type fuse

North-American built automobiles up to at least 1981 had electrical systems protected by cylindrical glass cartridge fuses rated 32 volts DC and current ratings from 4 amperes to 30 amperes. These are known as "SFE" fuses, as they were designed by the Society of Fuse Engineers to prevent the insertion of a grossly inadequate or unsafe fuse into the vehicle's fuse panel.[10][11] These SFE fuses all have a 14 inch diameter, and the length varies according to the rating of the fuse.

More information SFE designation, Rated current (A) ...
SFE designation Rated current (A) Length inches Notes
SFE 4 4 5/8 same length as any AGA rating
SFE 6 6 3/4
SFE 7.5 7.5 7/8 same length as any AGW rating
SFE 9 9 7/8 same length as any AGW rating
SFE 14 14 1 1/16
SFE 20 20 1 1/4 same length as any AGC rating
SFE 30 30 1 7/16
Close

There are a number of lookalike fuses which can easily be confused with these. In general this type of fuse will have an "AG" label of some kind, which originally stood for "Automobile Glass".[12][13] or "All Glass"[14] (sources conflict). AG-series fuses are rated for 125 VAC or 250 VAC, while SFE fuses are rated only to 32 V AC or DC and so are not intended for circuits connected to 120 or 250 VAC. There are at least seven different sizes of fuses with a 1/4 inch diameter. The fuses listed are the most common for the size, which is always a fast-acting fuse:

  • 1AG size, type AGA, 1 A to 30 A, 14 inch (6.4 mm) diameter by 58 inch (15.9mm) long[10]
  • 2AG size, type AGB, 0.177 in (4.5 mm) diameter by 0.588 in (14.9 mm) long (frequently replaced with 5mm diameter by 15mm long international size fuse (aka 5 x 15mm - now more readily available)[15]
  • 3AG size, type AGC, 0.125 A to 50 A, 14 inch (6.4 mm) diameter by 1+14 inches (32 mm) long[16]
  • 4AG size, type AGS, 932 inch (7.1 mm) diameter by 1+14 inches (32 mm) long[15]
  • 5AG size, type AGU, 1 A to 60 A, 1332 inch (10 mm) diameter by 1+12 inches (38 mm) long.[10] Also called "Midget fuses."[16]
  • 7AG size, type AGW, 1 A to 30 A, 14 inch (6.4 mm) diameter by 78 inch (22 mm) long[10]
  • 8AG size, type AGX, 1 A to 30 A, 14 inch (6.4 mm) diameter by 1 inch (25 mm) long[16]
  • 9AG size, type AGY, 50 A, 14 inch (6.4 mm) diameter by 1+716 inches (37 mm) long[10]
  • UK size, type UK, 35 A to 50 A, 14 inch (6.4 mm) diameter by 1+14 inches (32 mm) long[10]

These and other fuses are still being manufactured for many applications, including for AC circuits and DC uses. Some are time delayed, slow reacting, or have leads for terminals used in circuits without a fuse holder.[16][11] Many of the fuse dimensions and characteristics are published by the Society of Automotive Engineers as Standard SAE J 554.

Limiter type

Limiter fuses or fusible links consist of a metal strip for currents over 10 amperes. Also referred to as Current Limiting Fuses, they feature an internal fuse element that melts when current passing through the fuse element is within the specified current limiting range of the fuse. As the fuse element melts, it creates a high resistance to reduce the magnitude and duration of the current flowing through the fuse to protect the electrical circuit and connected equipment.[17] Frequently, these are used in close proximity to starter battery fuse boxes. They are used also in electric vehicles, e.g., in forklift trucks.

Indicating fuses

At least one manufacturer supplies fuses with a built-in lamp that lights when the fusible link has melted. This expedites identification of the blown fuse.

See also

References

Loading related searches...